Signal Conditioning/Transmitters - Back to Product Guide
Made in Santa Ana, CA
Electromagnetic Compatibility
Underwriter Laboratories
Underwriter Laboratories
Year 2000 Compliant
INFINITY Logo INFX - SURFACE MOUNT DISPLAYS
INFX Remote Display Remote display can be mounted in 1/8 DIN panel cutout or on surface mount bail

Mechanical Reference
INFX
Price List
INFZ
Price List

COMMON SPECIFICATIONS
Accuracy: ▒0.005% rdg
Span Temperature Coefficient: ▒20 ppm
Step Response: 1 sec to 99.9%
Warmup to Rated Accuracy: 50 min
Operating Ambient: 0 to 50░C, 95%RH, non-condensing
Storage Ambient: -40 to 85░C
Power: 230 Vac, 49-400 Hz; 10 to 32 Vdc
Power Consumption: 6 W nominal, 10 W max
Normal Mode Rejection: 60 dB
Common Mode Rejection: 120 dB
Common Mode Voltage: 1500 V peak per HV test
Resolution: 15-bit
Conversion: dual-slope technique
Reading Rate: 3/sec or 13/sec, 60 Hz; 3/sec or 12/sec, 50 Hz
Display: red or green 6-digit, 14-segment, 13.7 mm (0.54"); 4 alarm indicators
Dimensions: 48 H x 96 W x 165 mm D (1.9" x 3.8" x 6.5")
Panel Cutout: 45 H x 92 mm W (1.8" x 3.6"); 1/8 DIN
Weight: 574 g (1.27 lb)
TTL Outputs: four, isolated open collector; rated 150 mA at 1 V sink, 30 V open
BCD Output: isolated, tri-state, TTL/CMOS compatible; external 5 V supply for isolated; internal 5 V supply for non-isolated
Dual Relays: form C, 7 A at 30 Vdc or 230 Vac
Four Relay Option: dual 7 A relays and dual 1 A relays

Analog Output

0-5 V/1-5 V/0-10 V/ 0-20 mA/4-20 mA, user selectable; 354 Vp isolation; 15-bit resolution; 0.1% accuracy, 50 msec step response

RS-232 Communications

300/600/1200/2400/4800/9600/19.2k baud; RJ11 4-wire connection; complete program setup and message display capability; programmable to transmit current display, alarm status, min/max, actual measured input value and status

RS-485 Communications
300/600/1200/2400/4800/9600/19.2k baud; RJ12 6-wire connection; addressable from 0 to 199

PROCESS INPUTSùINFXU, INFXP, INFXS, INFXW
Voltage Input Ranges: 0-100 mV, 0-1 V, 0-5 V, 1-5 V, 0-10 V, 0-100 V, ▒50 mV, ▒500 mV, ▒5 V, ▒50 V
Current Input Ranges: 0-20 mA, 4-20 mA
Input Configuration: single-ended
Polarity: Unipolar/bipolar, programmable
Span Adjustment: 0.00001 to 500,000; programmable
Offset Adjustment: 0 to 999,999 or 0 to -99,999; programmable

TEMPERATURE INPUTSùINFXU, INFXT
Thermocouple Input Types: J, K, T, E, R, S, B, N, J DIN
RTD Input: any 6 to 6k ohm NIST or DIN platinum and any linear RTD
RTD Connection: 2, 3 or 4 wire
Sensor Break Protection: upscale or downscale, programmable
Overvoltage Protection: 25 V peak

SENSOR EXCITATIONùINFXP, INFXS, INFXU, INFXW
Sensor Excitation, INFXS, INFXU, INFXW: 10 V to 30 mA; 24 V to 25 mA Sensor Excitation, INFXP: 24 V to 25 mA


Models - INFXU, INFXP, INFXS, INFXW, INFZU, INFZP, INFZS, INFZW Models - INFXU, INFXT, INFZU, INFZT
Range Code
Range
Range Code
Range
DC1
0-100 mV
J (*)
J Iron-Constantan
DC2
0-1 V
K (*)
K CHROMEGA -ALOMEGA
DC3
0-5 V
E (*)
E CHROMEGA -Constantan
DC4
1-5 V
T (*)
T Copper-Constantan
DC5
0-10 V
B (*)
B Pt30%Rh-Pt6%Rh
DC6
0-100 V
R (*)
R Pt13%Rh-Pt
DC7
▒50 mV
S (*)
S Pt10%Rh-Pt
DC8
▒500 mV
N (*)
N Nicrosil-Nisil
DC9
▒5 V
J DIN (*)
J DIN Iron-Constantan
DC10
▒50 V
RTD1 (*)
RTD 10 ohm Copper
C1
0-20 mA
RTD2 (*)
RTD 100 ohmPt 0.00385
C2
4-20 mA
RTD (*)
RTD 100 ohm Pt 0.00392
* Specify C (Celsius), F (Fahrenheit) or K (Kelvin)
BackMore


Fast Quotes on Products
HOME / PRODUCT GUIDE / TECHNICAL REFERENCE
NEWPORT Electronics, Inc. (714) 540-4914 or Contact Us
Copyright 1999, Newport Electronics, Inc. All rights reserved.